Rotated optics available with packages P10, P11, P12 and P13. Must be combined with option L90 or R90.
-
30K, 40K, and 50K available in 70CRI and 80CRI. 27K and 35K only available with 80CRI. Contact Technical Support for other possible combinations.
-
T3LG, T4LG, BLC3, BLC4, LCCO, RCCO not available with option HS.
-
MVOLT driver operates on any line voltage from 120-277V (50/60 Hz).
-
HVOLT driver operates on any line voltage from 347-480V (50/60 Hz).
-
HVOLT not available with package P1 and P10 when combined with option NLTAIR2 PIRHN or option PIR.
-
XVOLT operates with any voltage between 277V and 480V (50/60 Hz).
-
XVOLT not available in packages P1 or P10.
-
SPA5 and RPA5 for use with #5 drilling only (Not for use with #8 drilling).
-
WBA cannot be combined with Type 5 distributions plus photocell (PER).
-
NLTAIR2 and PIRHN must be ordered together. For more information on nLight AIR2 visit this link
-
NLTAIR2 PIRHN not available with other controls including PIR, PER, PER5, PER7, FAO, BL30, BL50, DMG and DS. NLTAIR2 PIRHN not available with P1 and P10 using HVOLT. NLTAIR2 PIRHN not available with P1 and P10 using XVOLT.
-
PIR not available with NLTAIR2 PIRHN, PER, PER5, PER7, FAO BL30, BL50, DMG and DS. PIR not available with P1 and P10 using HVOLT. PIR not available with P1 and P10 using XVOLT.
-
PER/PER5/PER7 not available with NLTAIR2 PIRHN, PIR, BL30, BL50, FAO, DMG and DS. Photocell ordered and shipped as a separate line item from Acuity Brands Controls. See accessories. Shorting Cap included.
-
FAO not available with other dimming control options NLTAIR2 PIRHN, PIR, PER5, PER7, BL30, BL50, DMG and DS.
-
BL30 and BL50 are not available with NLTAIR2 PIRHN, PIR, PER, PER5, PER7, FAO, DMG and DS.
-
DMG not available with NLTAIR2 PIRHN, PIR, PER, PER5, PER7, BL30, BL50, FAO and DS.
-
DS not available with NLTAIR2 PIRHN, PIR, PER, PER5, PER7, BL30, BL50, FAO and DMG.
-
DS requires (2) separately switched circuits. DS provides 50/50 fixture operation via (2) different sets of leads using (2) drivers. DS only available with packages P8, P9, P10, P11, P12 and P13.
-
Reference Motion Sensor Default Settings table on page 4 to see functionality.
-
Reference Controls Options table on page 4.
-
HS not available with T3LG, T4LG, BLC3, BLC4, LCCO and RCCO distribution. Also available as a separate accessory; see Accessories information.
-
CCE option not available with option BS and EGSR. Contact Technical Support for availability.
-
Option HA not available with performance packages P4, P5, P7, P8, P9 and P13.
-
Requires luminaire to be specified with PER, PER5 or PER7 option. See Controls Table on page 4.